    Abstract
    In this research, a new nano graphene oxide based solid phase extraction followed by Dispersive Liquid-Liquid Microextraction was applied as simple, rapid and sensitive determination of trace amounts of Propranolol(PRO) in urine samples with HPLC-UVD. Several factors influencing the extraction of PRO, such as pH, adsorbent amounts, extraction time, organic
    [...] Read more.
    In this research, a new nano graphene oxide based solid phase extraction followed by Dispersive Liquid-Liquid Microextraction was applied as simple, rapid and sensitive determination of trace amounts of Propranolol(PRO) in urine samples with HPLC-UVD. Several factors influencing the extraction of PRO, such as pH, adsorbent amounts, extraction time, organic solvent type and the composition of solvent and desorption conditions were studied and optimized. Under optimum condition, the limit of detection (LOD) and limit of quantification (LOQ) of the proposed method were 2ng/mL?1 and 6.6ng/mL, respectively. Good linear behaviour over the investigated concentration ranges (2-2000ng/mL-1) and good correlation coefficient of 0.9901(r2) were obtained. The relative standard deviations (RSDs) based on three determinations at 2, 20, 200ng/ml-1 levels of PRO was less than 9.7 %. The findings of the present study may provide clinical and diagnostic laboratories.  Full article
    Figures

    Figure 1 of 6

    References
    [1]
    C.Jantarat, N.Tangthong, S.Songkro,G.P. Martin, R.Suedee, S-Propranolol imprinted polymer nanoparticle-on-microsphere composite porous cellulose membrane for the enantioselectively controlled delivery of racemic propranolol, International Journal of Pharmaceutics 349 (2008) 212?225.
    [2]
    G.G. Oliveira, D.C. Azzi, F.C. Vicentini, E.R. Sartori, O.F. Filho, Voltammetric determination of verapamil and propranolol using a glassy carbon electrode modified with functionalized multiwalled carbon nanotubes within a poly (allylamine hydrochloride) film, J. Electroanal. Chem. 708 (2013) 73?79.
    [3]
    J. Zhanga, L. Dinga, A. Wenb, F. Wua, L. Suna, L. Yang, An HPLC?ESI?MS method for the determination of propranolol in human plasma and its application to pharmacokinetic studies, Asian J. Pharm. Sci. 4 (2009) 169?177.
    [4]
    T. Alizadeh, L. Allahyari, Highly-selective determination of carcinogenic derivative of propranolol by using a carbon paste electrode incorporated with nano-sized propranolol-imprinted polymer, Electrochim. Acta 111 (2013) 663?673.
    [5]
    K. Scida, P.W. Stege, G. Haby, G.A. Messina, C.D. Garc?a, Recent applications of carbon-based nanomaterials in analytical chemistry: critical review, Anal.Chim. Acta 691 (2011) 6?7.
    [6]
    M. Valc?rcel, S. C?rdenas, B.M. Simonet, Y. Moliner-Mart?nez, R. Lucena,Carbon nanostructures as sorbent materials in analytical processes, TrAC,Trends Anal. Chem. 27 (2008) 34?43.
    [7]
    G.Z. Kyzas, A.Koltsakidou, S.G. Nanaki, D.N. Bikiaris, D.A. Lambropoulou ,Removal of beta-blockers from aqueous media by adsorption onto graphene oxide, Science of the Total Environment 537 (2015) 411 ?420.
    [8]
    B.H. Fumes, M.R. Silva, F.N. Andrade, C.E.D. Nazario, F.M. Lanc? as, Recent advances and future trends in new materials for sample preparation, TrAC,Trends Anal. Chem. 71 (2015) 9?25.
    [9]
    Q. Liu, J. Shi, G. Jiang, Application of graphene in analytical sample preparation, TrAC, Trends Anal. Chem. 37 (2012) 1?11.
    [10]
    G.Liu, W.Jiang, Y.Wang, S. Zhong, D. Sun, J. Liu, One-pot synthesis of Ag@Fe3O4/reduced graphene oxide composite with excellent electromagnetic absorption properties. Ceram. Int. 41(2015) 4982 ?4988.
    [11]
    A.A. Salem, I.A. Wasfi, S.S. Al-Nassibi, Trace determination of -blockers and 2-agonists in distilled and waste-waters using liquid chromatography?tandem mass spectrometry and solid-phase extraction, J. Chromatogr. B 908 (2012) 27?38.
    [12]
    M. Caban, P. Stepnowski, M. Kwiatkowski, N. Migowska, J. Kumirska, Determination of -blockers and -agonists using gas chromatography and gas chromatography?mass spectrometry?a comparative study of the derivatization step, J. Chromatogr. A 1218 (2011) 8110?8122
    [13]
    S. Zorita, P. Hallgren, L. Mathiasson, Steroid hormone determination in water using an environmentally friendly membrane based extraction technique, J.Chromatogr. A 1192 (2008) 1?8.
    [14]
    B. Huang, X.J. Pan, X. Wan, J.L. Liu, S.M. Zhao, P. Hu, F.R. Li, Simultaneous determination of steroid endocrine disrupting chemicals in water by solid phase extraction-derivatization-gas chromatographic?mass spectrometry, Chin. J. Anal. Chem. 39 (2011) 449?454.
    [15]
    Y. Nie, Z. Qiang, H. Zhang, C. Adams, Determination of endocrine-disrupting chemicals in the liquid and solid phases of activated sludge by solid phase extraction and gas chromatography?mass spectrometry, J. Chromatogr. A 1216 (2009)7071?7080.
    [16]
    W. Liu, Z. Yan, X. Huang, J. Chen, M. Lu, L. Zhang, G. Chen, Simultaneous determination of blockers and agonists by on-fiber derivatization in self-made solid-phase microextraction coating fiber, Talanta 132 (2015) 915?921.
    [17]
    P.C.F. Lima Gomes, B.B. Barnes, ?.J. Santos-Neto, F.M. Lancas, N.H. Snow, Determination of steroids, caffeine and methylparaben in water using solid phase microextraction-comprehensive two dimensional gas chromatography?time of flight mass spectrometry, J. Chromatogr. A 1299 (2013) 126?130.
    [18]
    L. Qiu, W. Liu, M. Huang, L. Zhang, Preparation and application of solid-phase microextraction fiber based on molecularly imprinted polymer for determination of anabolic steroids in complicated samples, J. Chromatogr. A 1217 (2010) 7461?7470.
    [19]
    K. Saito, K. Yagi, A. Ishizaki, H. Kataoka, Determination of anabolic steroids in human urine by automated in-tube solid-phase microextraction coupled with liquid chromatography?mass spectrometry, J. Pharm. Biomed. Anal 52 (2010)727?733.
    [20]
    L. Ciofi, D. Fibbi, U. Chiuminatto, E. Coppini, L. Checchini, M. del Bubba, Fully-automated on-line solid phase extraction coupled to high-performance liquid chromatography?tandem mass spectrometric analysis at sub-ng/L levels of selected estrogens in surface water and wastewater, J. Chromatogr. A 1283 (2013) 53?61.
    [21]
    F. Guo, Q. Liu, G. Qu, S. Song, J. Sun, J. Shi, G. Jiang, Simultaneous determination of five estrogens and four androgens in water samples by online solid-phase extraction coupled with high-performance liquid chromatography?tandem mass spectrometry, J. Chromatogr.A 1281 (2013) 9?18.
    [22]
    E. Pujos, C. Cren-Oliv?, O. Paisse, M.M. Flament-Waton, M.F.Grenier-Loustalot, Comparison of the analysis of -blockers by different techniques, J. Chromatogr. B 877 (2009) 4007?4014.
    [23]
    M. Rezaee, Y. Assadi, M.R. Milani Hosseini, E. Aghaee, F. Ahmadi, S. Berijani, Determination of organic compounds in water using dispersive liquid?liquid microextraction, J. Chromatogr. A 1116 (2006) 1?9.
    [24]
    L. Xu, X. Qi, X. Li, Y. Bai, H. Liu, Recent advances in applications of nano materials for sample preparation, Talanta 146 (2016) 714?726.
    [25]
    K. Scida, P.W. Stege, G. Haby, G.A. Messina, C.D. Garc?a, Recent applications of carbon-based nano materials in analytical chemistry: critical review, Anal.Chim. Acta 691 (2011) 6?17.
    [26]
    M. Valc?rcel, S. C?rdenas, B.M. Simonet, Y. Moliner-Mart?nez, R. Lucena, Carbon nanostructures as sorbent materials in analytical processes, TrAC, Trends Anal. Chem. 27 (2008) 34?43.
    [27]
    B.H. Fumes, M.R. Silva, F.N. Andrade, C.E.D. Nazario, F.M. Lanc? as, Recent advances and future trends in new materials for sample preparation, TrAC, Trends Anal. Chem. 71 (2015) 9?25.
    [28]
    Q. Liu, J. Shi, G. Jiang, Application of graphene in analytical sample preparation, TrAC, Trends Anal. Chem. 37 (2012) 1?11.
    [29]
    M. Cruz-Vera, R. Lucena, S. C?rdenas, M. Valc?rcel, Sorptive microextraction for liquid chromatographic determination of drugs in urine, TrAC, Trends Anal. Chem., 28 (2009) 1164-1173.
Filter options
Publication Date
From to
Refine Publication Date
Subject Areas
Refine Subjects
Article Types
Refine Article Types
Countries / Territories
Refine Countries / Territories